Service Summary
Intermediate Level Service Summary
Wet Running Inspection
□ Remove spa doors and turn on all equipment.
□ Pump and heater unions checked for leaks and tightened.
□ All JJ plugs and copper ground cables connected to motherboard
□ Venturi, diverter and neck jet valves all operate
□ All hose and PVC connections checked
□ All jet bodies and suction housing inspected for leaks
□ Check Peak/AO or Onzen generator is working properly. Check warranty status if they require changing.
□ Ensure all Jubilee clips (gear clamps) are tightened
□ Test chemical levels of water. Adjust if required. Only drain half water if necessary
□ All equipment running for 1 x 20 minute cycle
□ Topside is displaying current temperature
□ Pump 1 high and low speed functional
□ Pump 2 on/off functional
□ Pump 3 on/off functional
□ Blower on/off functional
□ Super Jet functional
□ Lights on/off
□ Northern lights/ Peyote lights functional (including all sequences)
□ Partial and full lock functional
□ Fahrenheit to Celsius functional
□ TA jets start with filtration cycle
□ All TA jets functional
□ TA jets checked for leaks
□ All equipment running
□ Diverters Distribute water equally
□ Diverters don’t leak at o-rings
□ All jets venturi when valve open
□ No jets venturi when valve closed
□ Light housing nuts checked for leaks
□ Arctic Ozone working and air moving through 3/8” line
□ Peak generator, circ. Pump working and flow from poly jet
□ MP3 / Wettunes operate correctly (customer has to supply MP or Ipod for testing).
□ Spa powered down and all fittings checked for leaks (wet stop test)
Final Inspection
□ Test chemical levels once more, add sanitizer if required.
□ All doors aligned
Terms & Conditions
Customer to provide access to a 240v mains supply within 10m of the spa for the connection of power tools. Customer to provide hose and water supply for filling of the spa & access to a drain point for disposing of water. Customer must ensure spa has adequate access to all sides before initial inspection & spa must be filled and running. Replacement parts not covered by warranty will be charged to the customer. Payment must be cleared and customers permission obtained before parts are installed. Site to be left clean and tidy by engineer (*where appropriate)